Back to top
Send SMS Send Inquiry
Insulation Monitoring Devices

Insulation Monitoring Devices

40000.00 - 50000.00 INR

Product Details:

  • Product Type Monitoring Devices
  • Material PVC
  • Application Electric
  • Voltage 240 Volt (v)
  • Color Green
  • Warranty Yes
  • Supply Ability : 1000 Piece Per Day
  • Click to view more
X

Price And Quantity

  • 40000.00 - 50000.00 INR
  • 100 Piece

Product Specifications

  • Electric
  • PVC
  • Yes
  • Green
  • Monitoring Devices
  • 240 Volt (v)

Trade Information

  • Cheque, Cash in Advance (CID), Cash Advance (CA)
  • 1000 Piece Per Day
  • 20 Days
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • Box
  • Africa, Middle East, Western Europe, Eastern Europe, South America, North America, Central America, Australia, Asia
  • All India

Product Description

Monitoring the status of ungrounded IT networks is a precondition for ensuring network safety and continuous operation, as required, in particular, in the health sector and in the heavy industries. The insulation monitoring devices monitor the insulation condition of the IT network and inform the operators immediately by acoustic or optical alarms about any insulation resistance decrease below the preselected Rcrit level (against the PE protective conductor).

The insulation monitoring devices (IMD) offered by Hakel are used for easy application in ungrounded IT power supply systems in metallurgy, civil engineering, shipbuilding, in hospitals, the transport environment, underground and surface mine

IT POWER SUPPLY NETWORK

IT power supply system is an insulated system that has all active parts isolated from the earth or one point of the network grounded via high impedance. Inactive parts of the electrical installation are grounded. Ungrounded system increases the operational reliability and human safety. Therefore it is used in the metallurgy, mechanical engineering, shipbuilding, traction systems, public transport and hospitals. The advantage of the ungrounded system is that the device connected to this system can work continuously even in the case of first fault (so-called earth fault). The phase voltage of the undamaged phase (or phases in the three-phase system) is increased to the value of the delta voltage during the first fault. The system is safe if inactive parts are properly grounded. The reason is that there occur no bigger than safe current levels. The relevant responsible person must be informed about this failure and the first fault must be eliminated as soon as possible. However, the second fault (double earth fault) must result in immediate disconnection of the power supply system. The insulation monitoring devices or residual current relays are used for monitoring of the ungrounded system. These devices indicate the insulation level decrease below the set value.


Allied Power Solutions

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



Allied Power Solutions
T-3, Third Floor,Pankaj Corner Plaza - III, I.P. Extension, Patparganj, Delhi - 110092, India
Phone :+918037301953
Mr. Anurag Gupta (Director)
Mobile :918037301953